Research on Calculation Methods of Building Envelope Thermal Characteristics

  • Authors

    • Gennadiy Farenyuk
    • Olena Filonenko
    • Volodymyr Datsenko
    2018-10-13
    https://doi.org/10.14419/ijet.v7i4.8.27221
  • density of heat flow rate, period of the variations, specific heat capacity, thermal resistance
  • Building envelope functional performance largely depends on the temperature fluctuation range on the interior surface. The aim of the calculation is to ensure that building envelope has the necessary thermal characteristics, which ensure maintaining almost stable temperature on the interior surface of the construction, under the periodic changes of environmental parameters. The dynamic thermal characteristics can also be used in the calculation of: the internal temperature in a room; the daily peak power and energy needs for heating or cooling; the effects of intermittent heating or cooling, etc. Exact prediction of building envelope temperature conditions under periodic thermal effects allows avoiding thermal failures. Calculation methods in the Ukraine state construction standards are significantly simplified. Currently, with return to furnace heating and other kinds of periodic heating, international standard calculation method is more important and requires revising the Ukrainian normative base.

     

     

  • References

    1. [1] Wargocki P., Wyon D., Matysiak B., Irgens S. (2005), The effects of classroom air temperature and outdoor air supply rate on performance of school work by children, Proceedings of Indoor Air, The 10th International Conference on Indoor Air Quality and Climate, Beijing, China, pp. 368-372.

      [2] Popiołek Z. (2005), Energy efficient development of the internal environment, Department of Heating, Ventilation and extraction techniques, Silesian University of Technology, Gliwice.

      [3] EN ISO 7730:2005 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria, 2005.

      [4] Marek Telejko, Ewa Zender-Åšwiercz (2017), Assessment of Thermal Comfort in a Building Heated with a Tiled Fireplace with the Function of Heat Accumulation. IOP Conf. Series: Materials Science and Engineering, available online: http://iopscience.iop.org/article/10.1088/1757-899X/245/5/052023/pdf.

      [5] Shklover A. (1996) Basics of building heat engineering of residential and public buildings, Moscow

      [6] Mazzeoa D., Olivetia G., De Simonea M., Arcuria N. (2015), Dynamic Thermal Characteristics of Opaque Building Components. A Proposal for the Extension of EN ISO 13786. available online: https://www.researchgate.net/publication/289533386_Dynamic_Theral_Characteristics_of_Opaque_Building_Components_A_Proposal_for_the_Extension_of_EN_ISO_13786 [accessed Sep 29 2018].

      [7] Gagliano A, Patania F, Nocera F, Signorello C. (2014), Assessment of the dynamic thermal performance of massive buildings. Energy and Buildings; 72: 361-70.

      [8] UNE-EN ISO 13786:2011 Thermal performance of building components - Dynamic thermal characteristics - Calculation methods (ISO 13786:2011)

      [9] NSTU-N B V.2.6-190:2013 (NSTU – National Standard of Ukraine) Manual on the estimation of design parameters of heat absorption and heat resistance of walling, (2013)

      [10] Shkirenko S, Muravlov V, Zyma O, “Design of Composite Skin Panels with Solar Panels on the Roofâ€, International Journal of Engineering & Technology, Vol.7, No 3.2, (2018), pp: 398-400. https://doi.org/10.14419/ijet.v7i3.2.14560

      [11] Yurin, O., Azizova A. & Galinska, T. (2018). Study of heat shielding qualities of a brick wall corner with additional insulation on the brick Paper presented at the MATEC Web of Conferences, , 230 https://doi.org/10.1051/matecconf/201823002039

      [12] Leshchenko M. V., Semko V. O. Thermal characteristics of the external walling made of cold-formed steel studs and polystyrene concrete. Magazine of Civil Engineering. № 8, (2015), pp. 44–55. https://doi.org/10.5862/MCE.60.6

      [13] Semko O., Yurin O., Avramenko Yu., Skliarenko S. Thermophysical aspects of cold roof spaces. MATEC Web of Conferences. Vol. 116, (2017), р. 02030. https://doi.org/10.1051/matecconf/201711602030

      [14] Yurin O., Galinska T. Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences. MATEC Web of Conferences. Vol. 116, (2017), р. 02039. https://doi.org/10.1051/matecconf/201711602039

      [15] Filonenko, O. (2018). Definition of the parameters of thermal insulation in the zone of building foundation according to the ground freezing depth. Energy Efficiency, 11(3), 603-626. doi:10.1007/s12053-017-9600-x

  • Downloads

  • How to Cite

    Farenyuk, G., Filonenko, O., & Datsenko, V. (2018). Research on Calculation Methods of Building Envelope Thermal Characteristics. International Journal of Engineering & Technology, 7(4.8), 97-102. https://doi.org/10.14419/ijet.v7i4.8.27221