Comparison of BLDC Motor Control with Fuzzy Tuning by Solar Power Input and Zeta Converter

  • Authors

    • Dr. D V V V Ch Mouli
    • K. Padmasri
    2018-12-29
    https://doi.org/10.14419/ijet.v7i4.42.25534
  • BLDC, Hall sensor signal, solarcell, Torque, zeta converter
  • The importance of brushless DC (BLDC) motor   along with its control is enhancing in present days due to its wide applications in sophisticated equipments. In this paper various parameters of the BLDC Motor was observed using open loop and closed feedback loop with Fuzzy and PI control. With the help of observed parameters, better controlling techniques are applied to BLDC Motor control. Solar power is used with Zeta converter in boost mode to give the power supply to the Motor. Using DC Generator the electrical loading is applied on BLDC Motor. The effect of closed loop control on Zeta converter was also analyzed. In present days the BLDC Motor drives are widely using   in aviation, defense, etc due to absence of commutator sparks. So high priority for better control of BLDC Motor in coordination with embedded designs is given due to its increasing utilization.

     

     

  • References

    1. [1] Kok Soon Tey, Saad Mekhilef, “Modified Incremental Conductance Algorithm for Photovoltaic System under Partial Shading Conditions and Load Variationâ€, IEEE Trans On Industrial Electronics, Vol. 61, No. 10, pp.5384-5392, October 2014

      [2] Rajan kumar , Bhim singh , “Single Stage Solar PV Fed Brushless DC Motor Driven Water Pumpâ€, IEEE Journal Of Emerging and Selected Topics In Power Electronics, Vol. 5, No. 3, pp. 1377-1385, September 2017

      [3] R. Shanmugasundram, K. Muhammad Zakariah, And N. Yadaiah, “Implementation and Performance Analysis of Digital Controllers for Brushless DC Motor Drivesâ€, IEEE/ASME Trans on Mechatronics, Vol. 19, No. 1, pp. 213-224, February 2014

      [4] Xiahong Nian, Hang Zhang, “Regenerative Braking System of Electric Vehicle Driven by Brushless DC Motorâ€, IEEE Trans. On Industrial Electronics, Vol. 61, No. 10, pp. 5798- 5808, October 2014

      [5] C. Sheeba Joice, S.R.Paranjothi , V. Jawahar Senthil Kumar, “Digital Control Strategy for Four Quadrant Operation of Three Phase BLDC Motor With Load Variationsâ€, IEEE Trans on Industrial Informatics, Vol. 9, No. 2, pp.974-982, May 2013

      [6] Rajan Kumar, Bhim singh , “ BLDC Motor –Driven Solar PV Array- Fed Water Pumping System Employing Zeta Converterâ€, IEEE Trans. On Industry Applications, Vol.52, No.3, pp 2315-2322, May/June 2016

      [7] Salih Baris Ozturk, and Hamid A. Toliyat, “Direct Torque and Indirect Flux Control of Brushless DC Motorâ€, IEEE/ASME Trans On Mechatronics, Vol. 16, No. 2, pp. 351-360, April 2011

      [8] Ahmed Rubaai, Paul Young, “ Hardware/ Software Implementation Of Fuzzy - Neural – Network Self Learning Control Methods for Brushless DC Motor Drives †, IEEE Trans. On Industry Applications, Vol.52, No.1, pp. 414-424, Jan/Feb 2016

      [9] Ahmed Rubaai, Jan Jerry, “Hybrid Fuzzy Bang–Bang Mode Controller With Switching Function for Electric Motor Drive Applicationsâ€, IEEE Trans. On Industry Applications, Vol. 50, No. 3, pp. 2269 – 2276, May/June 2014

      [10] Amit Vilas Sant , K.R.Rajagopal , “PM Synchronous Motor Speed Control Using Hybrid Fuzzy-PI With Novel Switching Functionsâ€, IEEE Trans. On Magnetics, Vol. 45, No. 10, pp. 4672-4675, October 2009

  • Downloads

  • How to Cite

    D V V V Ch Mouli, D., & Padmasri, K. (2018). Comparison of BLDC Motor Control with Fuzzy Tuning by Solar Power Input and Zeta Converter. International Journal of Engineering & Technology, 7(4.42), 9-13. https://doi.org/10.14419/ijet.v7i4.42.25534