An Analysis of the Moisture Content of Internal Insulation Structures According to the Installation of Vapor Retarder Based on Meteorological Data by Region: Focused on South Korea

  • Authors

    • Hyang-In Jang
    • Kyung-Soo Kim
    • Soung-Wook Hong
    • Chang-Ho Choi
    2019-01-02
    https://doi.org/10.14419/ijet.v8i1.4.25129
  • Condensation, Outdoor meteorological data, ISO 13788, EN 15026, Moisture content.
  • In South Korea, concealed condensation evaluations are carried out based on the ‘condensation prevention design standards for apartment housing,’ which only consider evaluations of the surface condensation of a structure (temperature). In addition, the evaluations consider only the monthly average outdoor temperature upon classifying outdoor conditions into three regions, which will not yield accurate results in terms of an assessment of condensation. Furthermore, cases of condensation and reverse condensation occur frequently due to a lack of regulations concerning the installation of vapor retarding layers within internal insulation structures where multiple occurrences of condensation may develop. To analyze levels of condensation according to the meteorological conditions of each region regarding internal insulation walls according to the presence or absence of vapor retarding layers, this study collected meteorological data from 20 different regions in South Korea, and undertook evaluations using simulations. The conclusions of this research are as follows. 1) The results of extracting meteorological data factors to undertake evaluations of concealed condensation indicated that temperature, relative humidity, total solar radiation, diffuse sky radiation, wind speed, wind direction, and precipitation have relevance. 2) The results of concealed condensation simulation evaluations using the meteorological data of 20 regions of South Korea presented differences according to the meteorological characteristics of each region, with concealed condensation found to have a more sensitive effect on a structure in regions closer to the coast. 3) For internal insulation structures installed with vapor retarding layers, the incidence of concealed condensation was high in coastal regions; in the case of internal insulation structures that were not installed with vapor retarding layers, the incidence of concealed condensation was low in Southern regions where high temperatures were present. 4) The results of a comparative analysis indicated that across all regions, the incidence of concealed condensation was lowest in internal insulation structures installed with vapor retarding layers.

     

     

  • References

    1. [1] IOS 13788, Hygrothermal Performance of Building Components and Building Elements - Internal surface temperature to avoid critical surface humidity and interstitial condensation, (2012).

      [2] BS EN 15026, Hygrothermal Performance of Building Components and Building Elements. Assessment of moisture transfer by numerical simulation, (2007).

      [3] Ministry of Land, Infrastructure and Transport, Design Criteria for Condensation Control in Apartments, (2013).

      [4] Manzan M, Zandegiacomo De Zorzi, E & Lorenzi W (2015), Experimental and numerical comparison of internal insulation systems for building refurbishment. Energy Procedia 82, 493-498.

      [5] Guimarães AS, Delgado JMPQ, Azevedo AC & de Freitas VP (2018), Interface influence on moisture transport in buildings. Construction and Building Materials 162, 480-488.

      [6] Hong SW, Kim KS, Park CY & Jang HI (2018), Comparison Analysis of Interstitial Condensation Occurrence Rate by Regional Weather conditions - Focused on 9 Regions in Korea. International Journal of Engineering & Technology for Automobile Security 2(1), 1-6

      [7] Hong SW, Kang HS, Park CY & Jang HI (2017), A Study on the Effect of Material Properties Related to Liquid Transport on the Maximum Cumulative Condensation. Jornal of KIAEBS 11(6), 572-585

      [8] Kim KS, Jang HY, Park CY, Yoo DC & Choi CH (2017), Comparison of Total Moisture Content by Internal Condensation Evaluation Method. Jornal of KIAEBS 11(6), 558-571

      [9] Oh SM, Park SH & Joung KS (2017), Study on the Improvement Plans of Condensation Defect Examples in Apartment Building. Korea Journal of Air-Conditioning and Refrigeration Engineering 29(2), 82-88

      [10] Jeong CW, Kim HS, Jeong SH, Kim YT, Song DS, Comparison and Analysis of Domestic and Foreign Standards for Preventing the Condensation in Multi-residential House, 2013 Summer Annual Conference Journal of Air-Conditioning and Refrigeration Engineering, pp:514-519,

      http://www.sarek.or.kr/html/sub06_02b.jsp?yearmonth=2013&quarter=s

      [11] Hwang HJ, Kim JY, Lee JS (2011), A Study on the Foundation of the Standard of Temperature and Humidity for Preventing Condensation in Apartment Housings, Journal of LHI 2(3), 269-276

      [12] Choi YK & Ahn JB (2003), Forecast on internal condensation at balcony ceiling of super-high apartment building faced with open air. Korean Journal of Construction Engineering and Management 4(4), 155-163.

      [13] Jung HS, Kang MW, An SJ & Leigh SB (2002), Establishment of Design Standards for Preventing Condensation in the Underground Space, Journal of the Architectural Institute of Korea Planning & Design 18(1), 249-259

      [14] Lehmkuhl J, Kelm S, Bucci M & Allelein HJ (2016), Improvement of wall condensation modeling with suction wall functions for containment application. Nuclear engineering and design 299, 105-111.

      [15] Asadollahi A & Esmaeeli A (2018), Simulation of condensation and liquid break-up on a micro-object with upper and lower movable walls using Lattice Boltzmann Method. Physica A: Statistical Mechanics and its Applications 498, 33-49.

      [16] Ma X, Li X, Shao X & Jiang X (2013), An algorithm to predict the transient moisture distribution for wall condensation under a steady flow field. Building and Environment 67, 56-68.

      [17] You S, Li W, Ye T, Hu F & Zheng W (2017), Study on moisture condensation on the interior surface of buildings in high humidity climate. Building and Environment 125, 39-48.

      [18] Raaholdt RKK & Algaard E (2017), New National Museum in Oslo. Analysis of risk for condensation and possible mold growth in internal climatic sectioning walls and floors. Energy Procedia 132, 807-812.

      [19] Huang P, Chew Y, Chang WS, Ansell M, Lawrence M, Latif E & Du H (2018), Heat and moisture transfer behaviour in Phyllostachys edulis (Moso bamboo) based panels. Construction and Building Materials 166, 35-49

      [20] Annila PJ, Hellemaa M, Pakkala TA, Lahdensivu J, Suonketo J & Pentti M (2017), Extent of moisture and mould damage in structures of public buildings. Case studies in construction materials 6, 103-108.

  • Downloads

  • How to Cite

    Jang, H.-I., Kim, K.-S., Hong, S.-W., & Choi, C.-H. (2019). An Analysis of the Moisture Content of Internal Insulation Structures According to the Installation of Vapor Retarder Based on Meteorological Data by Region: Focused on South Korea. International Journal of Engineering & Technology, 8(1.4), 13-26. https://doi.org/10.14419/ijet.v8i1.4.25129