Denoising of Ecg Signals Using Fir & Iir Filter: a Performance Analysis

  • Authors

    • Dr. Chhavi Saxena
    • Dr. Avinash Sharma
    • Dr. Rahul Srivastav
    • Dr. Hemant Kumar Gupta
    2018-10-04
    https://doi.org/10.14419/ijet.v7i4.12.20982
  • Baseline Noise, ECG, FIR Filter, IIR Filter, Noise.
  • Electrocardiogram (ECG) signal is the electrical recording of coronary heart activity. It is a common routine and vital cardiac diagnostic tool in which in electric signals are measured and recorded to recognize the practical status of heart, but ECG signal can be distorted with noise as, numerous artifacts corrupt the unique ECG signal and decreases it quality. Consequently, there may be a need to eliminate such artifacts from the authentic signal and enhance its quality for better interpretation. ECG signals are very low frequency signals of approximately 0.5Hz-100Hz and digital filters are used as efficient approach for noise removal of such low frequency signals. Noise may be any interference because of movement artifacts or due to power device that are present wherein ECG has been taken. Consequently, ECG signal processing has emerged as a common and effective tool for research and clinical practices. This paper gives the comparative evaluation of FIR and IIR filters and their performances from the ECG signal for proper understanding and display of the ECG signal.

     

     

  • References

    1. [1] R.S Khandpur “Biomedical instrumentation hand book), 11th reprint 2008 Tata McGraw –Hill publication company Limited New Delhi. ISBN-13: 978-0-07-0473355-3.

      [2] Stephen J. chapman “MATLAB programming for engineers†3rd Reprint Edition 2003 by Thomson asia Pte Ltd., Singapore ISBN: 981-240-606-9.

      [3] Malindi, P.(2002) “Cancelling power line interference in electrophysiological signalsâ€. ECT Research Journal, 2.

      [4] Widrow B. and Hoff M.E. (1960), “Adaptive switching circuitsâ€, In IREWESCON Convention Record, pp. 96-104, New York.

      [5] Zhang Jiashu, Tai Heng-Ming, “Adaptive Noise Cancellation Algorithm for Speech Processingâ€, IEEE Transactions, pp 2489-2492, 2007.

      [6] Jigram H. Shah, Jay M. Joshi, “Digital signal processing†University science press laxmi publication company Limited New Delhi.

      [7] Suzanna M. M. Martens , Massimo Mischi, S. Guid Oei, ‘An Improved Adaptive Power Line Interference Canceller for Electrocardiography’ IEEE transactions on biomedical engineering, vol. 53, no. 11, November 2006.

      [8] Syed Zahurul Islam, Syed Zahidul Islam, Razali Jidin, Mohd. Alauddin Mohd. Ali, “Performance Study of Adaptive Filtering Algorithms for Noise Cancellation of ECG Signalâ€, IEEE 2009.

      [9] Kevin Buckley., " ECE5251 Biomedical Signal Processing", 2009

      [10] Kiyoshi Nishikawa and Hitoshi Kiya, "Noval Implementation Technique of RLS Algorithm for Improving Throughtput of Adaptive Filters, 1999.

      [11] ALI H. SAYED, "Adaptive Filters",2008

      [12] Hayes, Monson H., “Statistical Digital Signal Processing and Modeling", John Wiley and Sons, inc., 1996.

      [13] Chandra, Shanti, and Ambalika Sharma. "A computationally efficient approach for ECG signal denoising and data compression." In Control and System Graduate Research Colloquium (ICSGRC), 2017 IEEE 8th, pp. 22-27. IEEE, 2017.

      [14] Hashemi, Abdolkarim, Masoomeh Rahimpour, and Mahmoud Reza Merati. "Dynamic Gaussian filter for muscle noise reduction in ECG signal." In Electrical Engineering (ICEE), 2015 23rd Iranian Conference on, pp. 120-124. IEEE, 2015.

      [15] Lastre-Domínguez, Carlos, Yuriy S. Shmaliy, Oscar Ibarra-Manzano, and Luis J. Morales-Mendoza. "Unbiased FIR denoising of ECG signals." In Electrical Engineering, Computing Science and Automatic Control (CCE), 2017 14th International Conference on, pp. 1-6. IEEE, 2017.

      [16] Hesar, Hamed Danandeh, and Maryam Mohebbi. "ECG denoising using marginalized particle extended kalman filter with an automatic particle weighting strategy." IEEE journal of biomedical and health informatics 21, no. 3 (2017): 635-644.

  • Downloads

  • How to Cite

    Chhavi Saxena, D., Avinash Sharma, D., Rahul Srivastav, D., & Hemant Kumar Gupta, D. (2018). Denoising of Ecg Signals Using Fir & Iir Filter: a Performance Analysis. International Journal of Engineering & Technology, 7(4.12), 1-5. https://doi.org/10.14419/ijet.v7i4.12.20982