Patient monitoring system using power line carrier communication

  • Authors

    • R NiranjanKumar
    • G Praveen Kumar
    • S Nirmal Kumar
    • V Vibin
    2018-06-08
    https://doi.org/10.14419/ijet.v7i2.33.15494
  • Carrier Spread Multiple Spectrum, Ethernet Card, Orthogonal Frequency Division Multiplexing, PLC-Power Line Communication Carrier, Spread Spectrum.
  • Detection of changes due to movement in a real time video is very important tool. Patient movement & monitoring system is a system that is used to detect movement changes in patient. Those changes may be either abnormal behavior or unusual changes made by the patient in the absence of doctor. This paper presents the method of patient movement monitoring system for those patients that are taking medical treatment in both local and foreign hospitals with the help of frames comparison approach. In this project flex sensors are fixed in two hands of the patient when there is any movement in hands the sensor send information to the doctors by wireless communication. Glass setup with eye ball sensor is fixed in the patient’s eye when any motions in the eye the sensor sense the value and send information to the doctor. Mems is used to find the patients leg movement and all the information is wirelessly transferred through PLC communication module and monitored in PC. Heartbeat and the temperature sensors are used to find the heart rate and the temperature of the patient.

     

     

  • References

    1. [1] Kai Ishida, Minoru Hirose, EisukeHanada, †Investigation of Interference with Medical Devices by Power Line communication to promote its safe introduction to the clinical settingâ€, L. Med Syst,Vol.31,pp.219-213,2016

      [2] Ordinance For Radio act(in Japanese)

      [3] E. Hanada, S. Itogo, K.Takano and K. Kudou,â€Investication of the Quality of Hospital Electric Power supply and the Tolerance of medical Electric Devices to Voltage Dips,â€L.MedSyst, Vol 31. PP.219-213.2016

      [4] E.Hanada,T.Kudou and S.tsumoto,â€Installation of secure,Always Available Wireless LAN System as a Components of the Hospital communication infrastructure,â€J.Med,Syst,Vol 37.PP.9939.2017.

      [5] T.Shinbo,M.Miyazaki,M.Hirose,K.kokubo and H.kobayashiâ€Effects of power line communication System on medical equipment,â€IFMBE,Proceeding,Vol25,pp547-549,2017.

      [6] Precoding Method for Broadband PLC MIMO System of Eliminating Interference :

      [7] Jingxue Ran1 and Yufei Cao2 1Centre of Data, MinZu University of China, Beijing, 100081, China 2Information engineering college, MinZu University of China.

      [8] Application research of the power line carrier communication multiband based on G3 technology - Ping Hu, Shi Peng, Rong Lin, Yong Liu – 19-21-November 2016

      [9] Soy,D. Nordell, and S. S. Venkata, “Lines of communication,†IEEE Power Energy Mag., vol. 9, no. 5, pp. 65–73, Sep./Oct. 2011.

      [10] D.W.Rieken and M. R. Walker II, “Distance Effects in Low-Frequency Power Line Communicationsâ€, presented atIEEE ISPLC 2010: 14th IEEE InternationalSymposium on Power Line Communications and its Applications, Mar. 2010.

      [11] K.Razazian et al., “G3-PLC Specification for Powerline Communication: Overview, System Simulation and Field Trial Resultsâ€, presented at IEEE ISPLC 2010: 14th IEEE International Symposium on Power Line Communications and its Applications, Mar. 2010.

      [12] Lasciandare et al., “STarGRID â„¢: the first industrial system on chip platform full PRIME compliantâ€, presented at IEEE ISPLC 2010: 14th IEEE International Symposium on Power Line Communications and its Applications, Mar. 2010.

      [13] L. Yang and C. Feng, “Design of Traffic Lights Controlling System Based on PLC and Configuration Technologyâ€, presented at MINES 09 International conference on multimedia information networking and security, Nov 2009.

      [14] A.Sendin et al., “Strategies for PLC Signal Injection in Electricity Distribution Grid Transformersâ€, presented at IEEE ISPLC 2011: 15th IEEE International Symposium on Power Line Communications and its Applications, Apr. 2011.

      [15] Kim, B. Varadarajam, A. Dabak. “Performance Analysis and Enhancement of Narrowband OFDM Powerline Communications Systemsâ€. IEEE 2010.

  • Downloads

  • How to Cite

    NiranjanKumar, R., Praveen Kumar, G., Nirmal Kumar, S., & Vibin, V. (2018). Patient monitoring system using power line carrier communication. International Journal of Engineering & Technology, 7(2.33), 771-774. https://doi.org/10.14419/ijet.v7i2.33.15494