Voltage Oriented Control(VOC) Of The PWM Rectifier Using Active Filtering Function

  • Authors

    • S Md.Mazhar-Ul-Haq
    • Dr S.S.Tulasi Ram
    • Dr JBV.Subramanyam
    2018-04-17
    https://doi.org/10.14419/ijet.v7i2.19.15056
  • PWM Rectifier, Harmonic Reduction, voltage oriented control, active filtering function, dynamic performance
  • Pulse width modulation rectifier has gathered its demand during the recent years for modification needs of the ac-dc conversion systems need for industries, customer and power grid sectors. This bidirectional converter can act as ac to dc boost rectifier with near unity power factor at the grid side along with the regulated and ripple free output voltage at the dc side. This paper deals with the evaluation of control strategy called voltage oriented control with active filtering function, Total harmonic distortion (THD),dynamic performance and parameter sensitivity is studied theoretical concept is provided and results of computer simulations are given by using mat lab.

     

  • References

    1. [1] Lin, B., Tsay, S., and Liao, M., 2001, “Integrated Power Quality Compensator Based on Sliding Mode Controller,†Proceedings of EPE 2001 InternationalConference, Graz, France, Vol. 148,No. 3, pp. 237-244.

      [2] M.Bhattacharya,“Improvement of Power Quality Using PWM Rectifier,†International journal of scientific and Research Publi tions,Volume 4,Issue 7, July 2014

      [3] Malinowski, M., 2001, “Sensorless Control Strategiesfor Three-phase PWM Rectifiers,†Ph.D.Dissertation, Faculty of Electical Engineering, WarsawUniversity of Technology, Warsaw, Poland

      [4] Malinowski, M., Kazmierkowski, M. P., Hansen, S.,Blaabjerg, F., and Marques, G. D., 2001, “Virtual Flux Based Direct Power Control of Three-phase PWM Rectifiers,†IEEE Transactions on Industrial Applications, Vol. 37, No. 4, pp. 1019-1027.

      [5] Mossoba, J., and Lehn, P., 2003, “A Controller Architecturefor High Bandwidth Active Power Filters,†IEEE Transactions on Power Electronics, Vol. 18,No. 1, pp. 317-325.

      [6] Nava-Segura, A., Arellano-Padilla, J., 2000, “TransientPerformance of an Active Filter under HarmonicPower Variations,†Proceedings of ISIE2000 International Conference, Mexico.

      [7] Malinowski, M., Kazmierkowski, M. P., &Trzynadlowski, A.(2003). Review and comparative study of control techniquesfor three-phase PWM rectifiers.Mathematics and Computersin Simulation, 63(3), 349-361.

      [8] Malinowski, M., Kazmierkowski, M. P., & Trzynadlowski, A.M. (2003). A comparative study of control techniques forPWM rectifiers in AC adjustable speed drives. PowerElectronics, IEEE Transactions on18(6), 1390-1396.

      [9] Moutchou, M., &Mahmoudi, H. (2014). SensorlessExactInput-Output Linearization Control of the Induction Machine,Based on Parallel Stator Resistance and Speed MRASObserver, with a Flux Sliding Mode Observer.InternationalJournal on Electrical Engineering and Informatics, 6(2), 324.

      [10] Gaynor, P., & Acharya, P. (2013). Direct Power ControlSpace Vector Modulation Technique Suitable for TurbineOperating at Variable Speeds

  • Downloads

  • How to Cite

    Md.Mazhar-Ul-Haq, S., S.S.Tulasi Ram, D., & JBV.Subramanyam, D. (2018). Voltage Oriented Control(VOC) Of The PWM Rectifier Using Active Filtering Function. International Journal of Engineering & Technology, 7(2.19), 90-93. https://doi.org/10.14419/ijet.v7i2.19.15056