Investigation of Beam Column Joint with Beam Weak in Shear under Monotonic Loading

  • Authors

    • B Mounika
    • P Poluraju
    2018-04-18
    https://doi.org/10.14419/ijet.v7i2.20.13293
  • Ductility, Exterior joints, Monotonic loading, Shear reinforcement, Strong column weak beam concept
  • Earthquake affected structures, mostly failure occur at beam column joints (BCJ). BCJs are categorized according to their geometrical grouping as Interior, Exterior, and Corner joints. Exterior beam column joint (i.e., terminating the beam on one of the column faces) was the most vulnerable one with respect to the plane of loading. The present study aims at ductility behaviour of exterior BCJ with conventional reinforcement using the code IS 456-2000 and with special confining reinforcement using the Code IS 13920-2016. Four number of beam-column joint specimens are considered in which the first one is detailed as per IS 456-2000, the second one as per IS 13920-2016 and the other two with 50% and 30% reduction of shear reinforcement was provided while compared with the first specimen. It is mainly to satisfy the strong column-weak beam concept as the main parameter. The test was carried out on the loading frame with hinged conditions to the column both ends, and the load is applied at the tip of the beam. The experimental studies are proven with an analytical study carried out by finite element model by using ANSYS and disparate parameters are assessed both experimentally and analytically.

     

     

  • References

    1. [1] Prabu N & Kandasmy S, “Study on Behavior of RCC Beam Column Joint with Special Confinement Subjected to Static Loading Numerical Investigationâ€, International Journal of Innovative Research in Engineering & Management (IJIREM), Vol.3, No1, (2015), pp.186-190.

      [2] Tiwary AK & Mohan M, “Strengthening of Exterior Beam Column Joint with Modified Reinforcement Techniqueâ€, IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), Vol.1, N0.6, (2014), pp.32-37.

      [3] Chaudhari SV, Mukane KA & Chakrabarti MA, “Comparative study on Exterior RCC Beam Column Joint Subjected to Monotonic Loadingâ€, International Journal of Computer Applications, Vol.102, No.3, (2014), pp.34-39.

      [4] Patil SS, Konapure CG & Manakari SS, “A Study of R. C. C. Beam Column Junction Subjected to Quasi-Static (Monotonic) loadingâ€, IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), Vol.6, No.5, (2013), pp.149-158.

      [5] Gopal SR & Prabhavathy S, “Seismic Behavior of Exterior Beam-Column Joint using Mechanical anchorage under Reversal loadingâ€, IJST Transactions of Civil Engineering, Vol.38, No.C2, (2014), pp.345-358.

      [6] Rajaram P, Murugesan A & Thirugnanam GS, “Experimental Study on behavior of Interior RC Beam Column Joints Subjected to Cyclic Loadingâ€, International Journal of Applied Engineering Research, Dindigul, (2010), Vol.1, No.1, pp.49-59.

      [7] Manjunatha K, Nambiyanna B & Prabhakara R, “Ductility Behaviour of External SFRSCC Beam Column Joint- An Experimental Studyâ€, International Journal of Innovative Research in Science, Engineering and Technology, Vol.5, No.11, (2016), pp.19837-19844.

      [8] Asran AG, Hassan HE & Sabryfayed, “Numerical Investigation of RC Exterior Beam Colum Connections under Monotonic Loadsâ€, IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), Vol.13, No.1, (2016), pp.60-6.

      [9] Elahe E & Khosro F, “Behavior of reinforced concrete interior wide beam-column connections under lateral loading: A finite element studyâ€, International Journal of Engineering and Technology (IJET), Vol.9, No.3, (2017), pp.2559-2570.

      [10] Rao PK, Balaji KVGD, Raju GSSSV & Rao S, “Effect of Increase of Reinforcement Near Beam-Column Joints in Performance-Based Design of Low-Rise Buildingsâ€, International Journal of Engineering and Technology (IJET), Vol.9, No.3, (2017), pp.2605-2618.

      [11] IS13920:2016, Ductile Design and Detailing of Reinforced Concrete Structures Subjected to Seismic Forces – Code of Practice, Bureau of Indian Standards, New Delhi.

      [12] IS 456:2000, Indian Standard code of Practice- Plain and Reinforced Concrete, Fourth Revision, Bureau of Indian standards, New Delhi.

      [13] IS 10262 (2009): Guidelines for concrete mix design proportioning [CED 2: Cement and Concrete], Bureau of Indian Standards, New Delhi.

      [14] Subramanian N & Prakash DS, “Design of Joints in RC Structures with Particular Reference to Seismic Conditionsâ€, The Indian Concrete General, (2003).

  • Downloads

  • How to Cite

    Mounika, B., & Poluraju, P. (2018). Investigation of Beam Column Joint with Beam Weak in Shear under Monotonic Loading. International Journal of Engineering & Technology, 7(2.20), 182-188. https://doi.org/10.14419/ijet.v7i2.20.13293