Sizing a 3 kWp Retrofitted Grid-Connected Photovoltaic System: a Case Study in Tropical Malaysia

  • Authors

    • Hedzlin Zainuddin
    • Farah Liyana Muhammad Khir
    • NA Baharudin
    • ZAbd Rahman
    2019-12-24
    https://doi.org/10.14419/ijet.v7i4.14.27720
  • sizing, photovoltaic, inverter, grid-connected, energy yield.
  • The work presents a tropical case study of sizing 3 kWp retrofitted  grid-connected photovoltaic system (GCPV) installed in Klang, Malaysia. The sizing was based on customer’s budget requirement of RM 22, 500 and conducted through a designated mathematical approach. The mathematical approach involved technical aspects which aligns the voltage and current specifications of both PV array and inverter. Besides, this approach includes possible severe climatic condition of solar irradiance and ambient temperature variations. By implementing the sizing mathematical approach in this study, the final PV array configuration is 1 x 9 (1 parallel x 9 series). This study was also conducted to compare between the actual and the predicted energy yield to reflect customer satisfaction. Based on the result, the percentage differences are acceptable for February and March 2018. Interestingly, the percentage difference for January 2018 was over-predicted and the abnormality was suggested to be resulted from the inaccuracy of the Peak Sun Hour (PSH) estimation. In conclusion, this study is significant as an overview on the sizing and performance reliability of GCPV system in tropical Malaysia to meet up the customer satisfaction.

     

  • References

    1. [1] Sulaiman, S. I., Rahman, T. K. A., Musirin, I., Shaari, S., & Sopian, K. (2012). An intelligent method for sizing optimization in grid-connected photovoltaic system. Solar Energy, 86(7), 2067–2082.

      [2] Nordin, N. D., & Rahman, H. A. (2015). Pre-installation design simulation tool for grid-connected photovoltaic system using iterative methods. Energy Procedia, 68, 68–76.

      [3] Camps, X., Velasco, G., de la Hoz, J., & Martín, H. (2015). Contribution to the PV-to-inverter sizing ratio determination using a custom flexible experimental setup. Applied Energy, 149, 35–45.

      [4] Bakhshi, R., Sadeh, J., & Mosaddegh, H. R. (2014). Optimal economic designing of grid-connected photovoltaic systems with multiple inverters using linear and nonlinear module models based on Genetic Algorithm. Renewable Energy, 72, 386–394.

      [5] SEDA, M. (2011). Feed-In-Tariff (FiT). Retrieved June 7, 2018, from http://www.seda.gov.my.

      [6] Muhammad, N., Zakaria, N. Z., Shaari, S., & Omar, A. M. (2017). System Performance Modelling of a Grid-Connected Photovoltaic System in UiTM . Malaysia. International Journal on Advanced Science Engineering Information Technology, 7(4).

      [7] Hussin, M. Z., Omar, A. M., Zain, Z. M., & Shaari, S. (2013). Performance of Grid-Connected Photovoltaic System in Equatorial Rainforest Fully Humid Climate of Malaysia. International Journal of Applied Power Engineering (IJAPE), 2(3), 105–114.

      [8] Omar, A. M., Hussin, M. Z., Shaari, S., & Sopian, K. (2013). Energy Yield Calculation Of The Grid Connected Photovoltaic Power System 2 Problem Formulation. Computer Applications in Environmental Sciences and Renewable Energy, 162–167.

      [9] Experiences, C. (2016). Residential PV, (December).

      [10] Karami, E. (2017). Performance Analysis and Comparison of Different Photovoltaic Modules Technologies under Different Climatic Conditions in Casablanca. Journal of Fundamentals of Renewable Energy and Applications, 7(3).

      [11] SEDA, M. (2016). GUIDELINES AND OF THE S USTAINABLE E NERGY.

      [12] Malaysia, S. E. D. A. (SEDA). (2016). Solar Irradiation Data For Malaysia. Malaysia: Sustainable Energy Development Authority (SEDA) Malaysia.

      [13] Pekat. (2018). SEDA Certified Photovoltaic Service Provider. Retrieved April 1, 2018, from https://pekat.solarlog-web.com.my.

      [14] JinKO. (2013). JinKO Solar. Retrieved November 3, 2018, from https://www.jinkosolar.com/.

      [15] STECA. (2014). STECA Electronic. Retrieved November 3, 2017, from https://www.steca.com.

      [16] Hussin, M. Z., Omar, A. M., Zain, Z., Shaari, S., & Zainuddin, H. (2012). Design Impact of 6 . 08 kWp Grid-Connected Photovoltaic System at Malaysia Green Technology Corporation. International Journal of Electric and Electronic System Research, 5.


  • Downloads

  • How to Cite

    Zainuddin, H., Liyana Muhammad Khir, F., Baharudin, N., & Rahman, Z. (2019). Sizing a 3 kWp Retrofitted Grid-Connected Photovoltaic System: a Case Study in Tropical Malaysia. International Journal of Engineering & Technology, 7(4.14), 466-472. https://doi.org/10.14419/ijet.v7i4.14.27720