Experimental Study on Fibre-Reinforced Concrete Beam-Column Joint with Ductile Detailing Under Reverse Cyclic Loading

  • Authors

    • Pallab Das
    • S Choudhury
    2018-07-26
    https://doi.org/10.14419/ijet.v7i3.4.16189
  • beam-column joint, performance, fibre, load, displacement.
  • The behaviour of a beam-column (BC) joint in a moment resisting framed structure is the key criteria when the structure is subjected to seismic loading. In the past many research have been carried out to grasp the mechanism of failure of beam-column joint and methods to enhance the performance of beam-column joint have been developed. The provision of ductile detailing as prescribed in IS-13920: 1993 has been followed. Improvement of the performance of joint region has been studied by using additional reinforcement with different fibres. In the present study the performance of the BC joint is studied in terms of load vs. displacement curve, stiffness degradation vs. drift angle curve and energy dissipation by the BC joint using different types of fibres in the specimen. The laboratory testing of the concrete cubes and cylinders reinforced with different percentages of fibre volume have been implemented. Based on the test results, the selection of the optimum quantity of fibre that can be used in beam-column joint for each type of fibre has been done. The testing of the specimens of BC joints is carried out in cyclic actuator of capacity 100 kN. The fibres which have been used in the present study are carbon fibre, steel fibre and glass fibre. Percentages of the fibres that had been added to the specimen are carbon fibre (0.75%), steel fibre (0.75%) and glass fibre (0.50%) respectively and the control specimen made from ordinary concrete made of M25 mix concrete. The performance of the specimens reinforced with different type of fibres is then compared and the specimen showing desirable performance under cyclic loading is found out. It has been observed that the application of carbon fibres could improve the strength and ductility of BC joints appreciably.

     

     

  • References

    1. [1] Siva Chidambaram and Pankaj Agarwal, “Seismic behavior of hybrid fiber reinforced cementitious composite beam–column joints", Journal of Materials and Design, Vol.86, pp.771-781, 2015.

      [2] Bo Li, Eddie Siu-shu Lam, BoWu and Ya-yong Wang, "Experimental investigation on reinforced concrete interior beam–column joints rehabilitated by fibrocement jackets", Journal of Engineering Structures, Vol.56, pp.896-909, 2013.

      [3] Kularni and Patil, "A Novel Reinforcement Pattern for Exterior Reinforced Concrete Beam-Column Joint ", Proceedings of 3rd Nirma University International Conference on Engineering, Vol.51, pp.184-193, (NUICONE 2012).

      [4] Rahmani Kadarningsih, Imam Satyarno, Muslikh and Andreas Triwiyono, "Proposals of beam column joint reinforcement in reinforced concrete moment resisting frame : A literature review study", Proceedings of 2nd International Conference on Sustainable Civil Engineering Structures and Construction Materials, Vol.95, pp.158-171, 2014.

      [5] Al-Ostaa, Isa, Baluch and Rahman, "Flexural behavior of reinforced concrete beams strengthened with ultra-high performance fiber reinforced concrete", Journal of Construction and Building Materials, vol.134, pp.279-296, 2017.

      [6] Kharoob, Ghazy, Yossef, "Behavior of beam-high performance fiber reinforced CFST column joints", Journal of Thin-Walled Structures, Vol.113, pp.217-227, 2017.

      [7] Michael Cooa and Thanakorn Pheeraphan, "Effect of sand, fly ash and limestone powder on preplaced aggregate concrete mechanical properties and reinforced beam shear capacity", Journal of Construction and Building Materials,Vol.120, (2016), pp.581–592.

      [8] Constanze Röhm, Balthasar Novák, Saptarshi Sasmal, Ramanjaneyulu Karusala and Voggu Srinivas, "Behaviour of fibre reinforced beam-column sub-assemblages under reversed cyclic loading", Journal of Construction and Building Materials, Vol.36, (2012), pp.319–329.

      [9] Gregoria Kotsovou and Harris Mouzakis, "Exterior RC beam–column joints: New design approach", Journal of Engineering Structures, Vol.41, (2012), pp.307–319.

      [10] Roberto Realfonzo, Annalisa Napoli and Joaquín Guillermo Ruiz Pinilla, "Cyclic behavior of RC beam-column joints strengthened with FRP systems", Journal of Construction and Building Materials, Vol.54, (2014), pp.282–297.

      [11] Lee, Chiou and Shih, "Reinforced concrete beam–column joint strengthened with carbon fiber reinforced polymer", Journal of Composite Structures, Vol.92, pp.48-60, 2010.

      [12] Hayder Alaa Hasan, Neaz Sheikh and Muhammad Hadi, "Performance evaluation of high strength concrete and steel fibre high strength concrete columns reinforced with GFRP bars and helices", Journal of Construction and Building Materials, Vol.134, pp.297-310, 2017.

      [13] Jalil Shafaei, Abdollah Hosseini and Mohammd Sadegh Marefat, "Seismic retrofit of external RC beam–column joints by joint enlargement using prestressed steel angles", Journal of Engineering Structures, Vol.81, pp.265-288, 2014.

      [14] Muthuswamy and Thirugnanam, "Structural behaviour of hybrid fibre reinforced concrete exterior Beam-Column joint subjected to cyclic loading ", Journal of civil and structural engineering, Vol.4, No.3, pp.262-273, 2014.

      [15] Perumal and Thanukumari, "Seismic performance of hybrid fibre reinforced Beam - Column joint", Journal of civil and structural engineering, Vol.1, No.4, pp.749-779, 2010.

      [16] Vikrant Vairagade and Kavita Kene, "Experimental Investigation on Hybrid Fiber Reinforced Concrete", Journal of Engineering Research and Applications, Vol.2, No.3, pp.1037-1041, 2012.

      [17] Shwan Said and Hashim Abdul Razak, "Structural behavior of RC engineered cementitious composite (ECC) exterior beam–column joints under reversed cyclic loading", Journal of Construction and Building Materials, Vol.107, pp.226-234, 2016.

      [18] Ganesan, Indira and Sabeena, " Behaviour of hybrid fibre reinforced concrete beam–column joints under reverse cyclic loads", Journal of Materials and Design, Vol.54, pp.686-693, 2014.

  • Downloads

  • How to Cite

    Das, P., & Choudhury, S. (2018). Experimental Study on Fibre-Reinforced Concrete Beam-Column Joint with Ductile Detailing Under Reverse Cyclic Loading. International Journal of Engineering & Technology, 7(3.16), 85-89. https://doi.org/10.14419/ijet.v7i3.4.16189