Designing Early Warning System for The Impact of Industrial Development Waste by Using pH Control System

  • Authors

    • Veronika Nugraheni Sri Lestari
    • Dwi Cahyono
    • Sri Susilowati
    2018-04-15
    https://doi.org/10.14419/ijet.v7i2.11581
  • Industry building, environment, microcontrollers, pH control.
  • Environment is inseparable from human life. Human negligence in building industry without caring the impact on environment can damage the physical and biological environment slowly and indirectly. Therefore an effort to preserve the quality of environment, especially for the environment adjacent to the settlement, is necessary and can be performed in various ways including technology utilization. Technology develops rapidly and electronic devices have become one compulsory device to be owned. Wastewater is industrial waste should be controlled prior to passing surrounding environment to avoid pollution. One way to control it is controlling its pH of, this is performed by early warning on pH level. This paper focused on designing control device for industrial waste water pH that is able to inform an early when on concentration of industrial waste water under normal limit water.

  • References

    1. [1] C. R. Dempsey and E. T. Oppelt, “Incineration of hazardous waste: a critical review update,†Air Waste, vol. 43, no. 1, pp. 25–73, 1993.

      [2] Z. Bian, J. Dong, S. Lei, H. Leng, S. Mu, and H. Wang, “The impact of disposal and treatment of coal mining wastes on environment and farmland,†Environ. Geol., vol. 58, no. 3, pp. 625–634, 2009.

      [3] DFRobot, “PH meter V1.1 SKU:SEN0161,†2014. [Online]. Available: https://www.dfrobot.com/wiki/index.php/PH_meter_V1.1_SKU:SEN0161. [Accessed: 25-Mar-2014].

      [4] S. A. Latif, SIG Fasilitas Umum di Bojonegoro Berbasis Android. Surabaya: Universitas Dr. Soetomo, 2013.

      [5] A. S. Ahmar and A. Rahman, “Development of teaching material using an Android,†Glob. J. Eng. Educ., vol. 19, no. 1, 2017.

      [6] G. N. U. G. P. License, “The GNU Operating system,†URL http//www. gnu. org/licenses/gpl. html (дата Ð¾Ð±Ñ€Ð°Ñ‰ÐµÐ½Ð¸Ñ 21.03. 10), 2008.

      [7] A. S. Ahmar, Rusli, and A. Rahman, “Steps in Designing Queue and Interview Process using Information System: A Case of Re-registration of New Students in Universitas Negeri Makassar,†Asian J. Technol. Manag., vol. 9, no. 1, pp. 52–57, 2016.

      [8] A. S. Ahmar, A. Rahman, A. N. M. Arifin, and A. A. Ahmar, “Predicting movement of stock of ‘Y’ using sutte indicator,†Cogent Econ. Financ., vol. 5, no. 1, 2017.

      [9] M. N. Rao, “Temperature based fan speed control and observing utilizing arduino,†Int. J. Eng. Technol., vol. 7, no. 1.1, pp. 685–688, 2017.

      [10] P. S. S. Teja, M. Vineel, G. Manisha, and S. Satyanarayana, “Automated irrigation system using sensors and node micro controller unit,†Int. J. Eng. Technol., vol. 7, no. 1.1, pp. 240–242, 2017.

  • Downloads

  • How to Cite

    Sri Lestari, V. N., Cahyono, D., & Susilowati, S. (2018). Designing Early Warning System for The Impact of Industrial Development Waste by Using pH Control System. International Journal of Engineering & Technology, 7(2), 555-558. https://doi.org/10.14419/ijet.v7i2.11581