Compensation of voltage Sag using STATCOM

  • Authors

    • Savitha Venkatesan
    • Booma Nagarajan
    2018-03-19
    https://doi.org/10.14419/ijet.v7i2.8.10554
  • Power quality, Voltage Source Converter, Static Synchronous Compensator, Voltage Sag, Non-linear load.
  • Due to unpredicted non-linear loads, power quality problems, a raise in the transmission system. One such problem is voltage sag. Voltage sag is caused by the non-linear load which demands reactive power, but the balanced 3F source provides required reactive power of the load with reduced voltage at the receiving end. In this paper, simulation study has been performed to reducethe voltage sag issue. A transmission system with generation source with different loading conditions is considered and study has been done. A 3F medium P model transmission line is designed with a power source of 11kV.  A shunt connected compensation unit called Static Synchronous Compensator (STATCOM) reduces the voltage sag in the transmission line. STATCOM provides the required reactive power demanded by the non-linear load along with the source for compensation of voltage sag. The STATCOM circuit comprises of Voltage source converter(VSC) unit and a DC source. Reactive power compensation is done by VSC unit firing angle control. The source of the STATCOM can also be from renewable energy system. This AC source is converted by a AC-DC-AC converter unit.The firing angle is controlled by the control unit which ensures the continuous and balanced power flow even under sudden change in load conditions. The simulation results depict the characteristics of the developed STATCOM.

  • References

    1. [1] Ana Maria Zornita de Alencar, Martin Cruz Rodriguez Paz,“Analysis of the STATCOM use to Mitigate the Effectsof Voltage Sags on the Wind Farms Operation. AStudy Case†(2016).

      [2] Abhayrajsinh J. Rana, Indrajit N. Trivedi, “Application ofD-STATCOM for Power Quality Improvement in Distribution Line†(2016).

      [3] J.C Das,“Application of STATCOM to an industrial distribution system connected to a weak utility†(2016)

      [4] BagchiS, BhaduriR, “Analysis of Power Transfer Capability of a Long Transmission Line using FACTS Devices†(2015).

      [5] Meenakshi Rastogi, Abdul Hamid Bhat,“Reactive Power Compensation Using StaticSynchronous Compensator (STATCOM) withConventional Control Connected with 33kV Gridâ€(2015).

      [6] N.Nirmala, V.Suresh Kumar,“A STATCOM-Control Scheme forWind Energy System to Improve Power Quality†(2013).

      [7] Manoj Kumar Swainetet al.“Enhancement of Power Quality for Grid Connected Wind Energy System using Smart-STATCOM†(2014).

      [8] Bhargav.Aet al.“Power Quality Improvement using STATCOM with Renewable Energy Sourcesâ€(2012).

      [9] R.Vinotha et al. “Power quality improvement using DSTATCOMâ€(2012).

      [10] Bhargav.Aet. el. “Power Quality Improvement using STATCOM with Renewable Energy Sourcesâ€(2013).

      [11] A.Yanushkevichet et al.“Power Quality Enhancement using STATCOM with Energy Storage†(2012).

      [12] RavikantPandeyet et al.“Power quality improvement using CHBMLI based D-STATCOM†(2015).

      [13] Vinod, S. Tejwaniet, “Power Quality improvement in power distribution system using D-STATCOM†(2013).

      [14] Umesh Kumar Soniet et al.“Power Quality Improvement using PID based Reference Voltage Compensation with STATCOM†(2013).

      [15] RajeshRajanet et al.“Power quality improvement in grid connected wind energy system using STATCOM†(2013).

      [16] IlangoK etal.“Power Quality Improvement using STATCOM with Renewable Energy Sources†(2012).

      [17] HendriMasdietal.“Design of a Prototype D-STATCOM for Voltage SagMitigation†(2004).

      [18] HendriMasdiet et al.“Design of a Prototype D-STATCOM using DSP Controllerfor Voltage Sag Mitigation†(2005).

      [19] Wei Qiao, Ronald G. Harley, “Power Quality and Dynamic Performance Improvement of Wind Farms Using a STATCOM†(2007).

      [20] Paulraj.T, Infant Santhosh Sherin, “Mitigation of Power Loss in Transmission andDistribution Line Using STATCOM†(2016).

      [21] Piyushkumar M. Saradva,Ketan T. Kadivar,“Application of D-STATCOM to Control Power Flow in Distribution Line†(2016).

      [22] E.E.C. Moraes, S.J. de Mesquita, “The Application of D-STATCOM in Smart Distribution Grid with Wind Power Plants†(2016).

      [23] K. Ramash Kumar,â€Implementation of Sliding Mode Controller plus Proportional Integral Controller for Negative Output Elementary Boost Converter,†Alexandria Engineering Journal (Elsevier), 2016, Vol. 55, No. 2, pp. 1429-1445.

      [24] P. Sivakumar, V. Rajasekaran, K. Ramash Kumar, “Investigation of Intelligent Controllers for Varibale Speeed PFC Buck-Boost Rectifier Fed BLDC Motor Drive,†Journal of Electrical Engineering (Romania), Vol.17, No.4, 2017, pp. 459-471.

      [25] K. Ramash Kumar, D.Kalyankumar, DR.V.Kirbakaran†An Hybrid Multi level Inverter Based DSTATCOM Control, Majlesi Journal of Electrical Engineering, Vol. 5. No. 2, pp. 17-22, June 2011, ISSN: 0000-0388.

      [26] S.V.Manikanthan and V.Rama, “Optimal Performance Of Key Predistribution Protocol In Wireless Sensor Networks†International Innovative Research Journal of Engineering and Technology ,ISSN NO: 2456-1983,Vol-2,Issue –Special –March 2017.

      Padmapriya and V. Saminadan, “Improving Throughput for Downlink Multi user MIMO-LTE Advanced Networks using SINR approximation and Hierarchical CSI feedbackâ€, International Journal of Mobile Design Network and Innovation- Inderscience Publisher, ISSN : 1744-2850 vol. 6, no.1, pp. 14-23, May 20 15.
  • Downloads

  • How to Cite

    Venkatesan, S., & Nagarajan, B. (2018). Compensation of voltage Sag using STATCOM. International Journal of Engineering & Technology, 7(2.8), 673-676. https://doi.org/10.14419/ijet.v7i2.8.10554